RME Audio Advanced Remote Control Guide de l'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 112
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
14
User's Guide Fireface UCX © RME
Buffer Size
The setting Buffer Size determines the latency between incoming and outgoing ASIO and WDM
data, as well as affecting system stability (see chapter 9.1).
Errors does not refer to buffer errors, but USB and FireWire transmission errors. The display
will be reset on any start of a playback/record. More information can be found in chapter 37.3 /
37.4.
Output Format
Word – Single Speed
The word clock output signal usually equals the current sample rate. Selecting Single Speed
causes the output signal to always stay within the range of 32 kHz to 48 kHz. So at 96 kHz and
192 kHz sample rate, the output word clock is 48 kHz.
Optical
The optical TOSLINK output can operate as ADAT or SPDIF output. The Channel Status is
fixed to Consumer state.
Note
: The optical input detects the incoming format automatically, see Input Status.
SPDIF
The coaxial SPDIF output can have the Channel Status Consumer or Professional. For further
details please refer to chapter 21.2.
Options
DSP – EQ+D for Record
Switches EQ and Dynamics of all input channels into the recording path. In case Loopback has
been activated the EQ and Dynamics of the Output channel are within the recording path. See
also chapter 27.5.
SPDIF In - TMS
TMS activates the transmission of Channel Status data and Track Marker information from the
SPDIF input signal.
Word In - Termination
Checking this option terminates the word clock input internally with 75 Ohms.
Clock Mode
Sample Rate
Sets the currently used sample rate. Offers a central and comfortable way of configuring the
sample rate of all WDM devices to the same value, as since Vista the audio software is no
longer allowed to set the sample rate. However, an ASIO program can still set the sample rate
by itself.
During record/playback the selection is greyed out, so no change is possible.
Clock Source
The unit can be configured to use its own clock (Internal = Master), or one of the input signals
(Word, SPDIF coax., Optical In). If the selected source isn't available (Input Status No Lock),
the unit will change to the next available one (this behaviour is called AutoSync). If none is
available then the internal clock is used. The current clock source is displayed as Current.
Pitch
More information on Pitch is available in chapter 7.2.
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 111 112

Commentaires sur ces manuels

Pas de commentaire